Design and Analysis of Diagrid and Shear Wall Structures Subjected to Seismic Loads
Thota Sai Charan1, Dumpa Venkateswarlu2, Rayi Chandra Shekar3

1Thota Sai Charan, Department of Civil Engineering, Godavari Institute of Engineering and Technology, Rajahmundry, India. 
2Dr. Dumpa Venkateswarlu, Department of Civil Engineering, Godavari Institute of Engineering and Technology, Rajahmundry, India.
3Rayi Chandra Shekar, Department of Civil Engineering, Godavari Institute of Engineering and Technology, Rajahmundry, India.

Manuscript received on 23 August 2019. | Revised Manuscript received on 05 September 2019. | Manuscript published on 30 September 2019. | PP: 3725-3733 | Volume-8 Issue-11, September 2019. | Retrieval Number: K25670981119/2019©BEIESP | DOI: 10.35940/ijitee.K2567.0981119
Open Access | Ethics and Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: The advancement of tall structures depends on new basic ideas with recently received high quality materials and development techniques have been towards “firmness” and “gentility”. According to the past records of quakes, there is an expansion in the interest for utilization of seismic tremor opposing structures. So it is important to plan and dissect the structures by thinking about seismic impact. Presently a-days, shear dividers are utilized because of its opposing properties. The utilization of the shear divider framework in fortified solid structures is utilized to limit seismic outcomes. Plus, the diagrid frameworks are utilized for similar reasons in auxiliary structures. Albeit the two frameworks are utilized to defeat similar impacts, yet two frameworks will displays diverse conduct against seismic burden. The present work is worried about the similar investigation of seismic examination of multi-celebrated structure with diagrid and shear divider framework in various zones. The present examination is to comprehend that the structures need appropriate Earthquake opposing highlights to securely oppose huge horizontal powers that are forced on them during Earthquake. Shear dividers and diagrid are productive and compelling in limiting harm in structures because of quake and wind. The investigation centers around correlation of execution of diagrids and shear dividers in tall structure. Displaying and investigation of the structure is done in ETABS 2016 programming in various seismic zones and wind conditions. For examination different IS codes have been alluded, for Gravity load blend IS 456:2000 and for seismic burden mixes according to IS1893:2002 (section 1) code is alluded. To dissect the structures, the dynamic examination technique is embraced. The reaction range and Non-straight time history capacities are characterized to do dynamic investigation. The consequence of models are organized and graphically spoke to and is analyzed for deciding the better execution of structure against horizontal burdens.
Keywords: Diagrid wall, Shear wall, Sesmic Loads
Scope of the Article: Software Analysis, Design and Modelling