Wind Analysis of Composite Building with Bracing System
Mayank Walia1, Supervisor Nirbhay Thakur2, Nitish Kumar Sharma3
1Mayank Walia, PG Student, Civil Department, Chandigarh University Gharuan, Mohali (Punjab), India.
2Nirbhay Thakur, Supervisor ER. Assistant Professor, Civil Department, Chandigarh University Gharuan, Mohali (Punjab), India.
3Nitish Kumar Sharma, Co-Supervisor ER. Assistant Professor, Civil Department, Chandigarh University Gharuan, Mohali (Punjab), India.
Manuscript received on 02 June 2019 | Revised Manuscript received on 10 June 2019 | Manuscript published on 30 June 2019 | PP: 1399-1404 | Volume-8 Issue-8, June 2019 | Retrieval Number: H7107068819/19©BEIESP
Open Access | Ethics and Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
Abstract: The present investigation shows the research work carried out on the composite structure provided with bracing system. For this investigation, 12 storey irregular building and 16 storey regular building were modelled in staad.pro design software with different types of bracing (i.e. cross bracing, V-type bracing and zigzag bracing) at the edges of the building to provide lateral stability. For this study, steel framed structure was proposed for upper 4 storey of 12 storey building and 16 storey building in order to reduce the dead weight of the structure and wind analysis was performed. All the members were studied in a scrutinized way after the analysis from the post-processing of staad.pro and the performance of the structure was evaluated. The effectiveness of bracing system and introduction of steel framed structure in RCC building was concluded as the final outcome of the present investigational study. In the gist, it has been concluded that minimum displacement was found out in type A and type X building which entails cross type bracing which has proved to be more effective than V type and zigzag type bracing. And building having zigzag bracing entails minimum total quantity whereas, building having cross bracing system uses maximum material quantity. There was slight variation in % of steel as the column sizes were same for same type of building i.e 12 storey irregular building and 16 storey regular building.
Keyword: Wind Analysis, Composite Structure, Bracing System, Staad.Pro.